beautypg.com

Hardware enable circuitry (vector control only) – Rockwell Automation 20L PowerFlex 700L Frame 1X Liquid-Cooled Adjustable Frequency AC Drive User Manual

Page 29

background image

PowerFlex 700L Frame 1X Drive Installation Instructions – Publication 20L-IN013A-EN-P – June 2009

29

By default, the user can program a digital input as an Enable input. The
status of this input is interpreted by drive software. If the application
requires the drive to be disabled without software interpretation, a
“dedicated” hardware enable configuration can be used. This is done by
removing a jumper and wiring the enable input to “Digital In 6.”

1. Remove the drive Main Control Board (see

Figure 11

).

Figure 11

Main Control Board Removal

Hardware Enable Circuitry (Vector Control Only)

U

T1

U

V

W

V

T2

OUTPUT

W

T3

BR2

BR1

T

S

R

Flathead Screw

M4 x 12 mm Long

2X (apply Loctite to threads)

1.9 N

m (17 lb

in)

Flathead Screw

M4 x 10 mm Long

2X

1.9 N

m (17 lb

in)

Flathead Screw
M4 x 10 mm Long
1X
1.9 N

m (17 lb

in)

Flathead Screw

M4 x 10 mm Long

4X

1.9 N

m (17 lb

in)