Alternate linear list access method – Rockwell Automation 20-HIM-C6S PowerFlex (Human Interface Module) User Manual
Page 43
Rockwell Automation Publication 20HIM-UM001D-EN-P - February 2013
43
Using the HIM
Chapter 4
6.
Press the EDIT
soft key (for editable parameters only) to display the Edit
Parameter pop-up box.
Figure 11 - Example Edit Parameter Pop-Up Box
7.
Use the numeric keys, decimal
soft key, and soft key to edit the parameter.
8.
Press the ENTER
soft key to enter the new parameter value and return to
the parameter screen.
Alternate Linear List Access Method
1.
Access the Status screen (see
Figure 6
).
2.
Use the
or
key to scroll to the Port of the device whose
parameters you want to access (for example, Port 00 for the host drive).
3.
Press the
key to display its last-viewed folder.
4.
Use the
or
key to scroll to the PARAMETER folder.
5.
Use the
or
key to select Linear List.
6.
Press the
(Enter) key to display either the device’s last-viewed
parameter or the first parameter in the linear list.
7.
Use the
or
key to scroll to the desired parameter.
8.
Press the EDIT
soft key (for editable parameters only) to display the Edit
Parameter pop-up box (
).
9.
Use the numeric keys, decimal
soft key, and soft key to edit the parameter.
10.
Press the ENTER
soft key to enter the new parameter value and return to
the parameter screen.
TIP
When the decimal soft key is pressed while editing a numeric value,
this key temporarily changes to an EXP soft key to allow exponential
entry.
TIP
When the decimal soft key is pressed while editing a numeric value,
this key temporarily changes to an EXP soft key to allow exponential
entry.
Edit Accel Time 1
5.0 Secs
0.00 << 3600.00
ESC
.
Stopped
0.00 Hz
AUTO
F
ENTER