Using the HIM

Chapter 4

7.

Use the

or

key to select the appropriate action.

• Host and Ports (Preferred):

Selects the host device and all ports for a

factory default action.

• This Port Only:

Selects only this port for a factory default action.

8.

Press the

(Enter) key to display the warning pop-up box to reset

defaults.

Setting PowerFlex 7-Class Drives/Peripherals to Factory Defaults

1.

Access the Status screen (see

Figure 6

).

2.

Use the

or

key to scroll to the Port of the device whose

parameters you want to set to factory defaults (for example, Port 00 for the
host drive or the respective port number for one of the drive’s connected
peripherals).

3.

Press the

key to display its last-viewed folder.

4.

Use the

or

key to scroll to the MEMORY folder.

5.

Use the

or

key to select Set Defaults.

6.

Press the

(Enter) key to display the Set Defaults pop-up box.

7.

Press the ENTER

soft key to affirm and set all device parameter values to

factory defaults—or press the ESC

soft key to cancel.

TIP

For a description of a selected menu item, press the INFO soft key.

Figure 9 - ‘Host and Ports (Preferred)’ Pop-Up Box

Press the ENTER soft key to affirm and set most parameters
for the host drive and port devices to factory defaults. In this
case, see the host drive and port device documentation for
the settings that will not be restored—or press the ESC soft
key
to cancel.

Figure 10 - ‘This Port Only’ Pop-Up Box

Press the MOST soft key to set most settings for the selected port
device to factory defaults. In this case, see the host drive
documentation for the settings that will not be restored. Press
the ALL soft key to set all settings for the selected port device to
factory defaults—or press the ESC soft key to cancel.

Stopped

0.00 Hz

AUTO

F

WARNING

Sets most parameters in the

Host device and all ports

to factory defaults.

Continue?

ESC

ENTER

Stopped

0.00 Hz

AUTO

F

MOST

ALL

WARNING

Use MOST to reset typical

settings on this port

(preferred). Use ALL to

reset all settings.

ESC

Stopped

0.00 Hz

AUTO

F

WARNING

Sets all parameters to

factory defaults.

Continue?

ESC

ENTER