Main screens, Status screen – Rockwell Automation 20-HIM-C6S PowerFlex (Human Interface Module) User Manual
Page 26

26
Rockwell Automation Publication 20HIM-UM001D-EN-P - February 2013
Chapter 3
HIM Components
Main Screens
The HIM main screens include the Status screen, Process screen, Control screen,
Folder screens, and Fault Display screens, which are described in their respective
subsections that follow.
Status Screen
On power up, the Status screen (
Figure 4
) is shown by default. Depending on the
type of host drive, the Status screen displays the following information.
Figure 4 - Example Status Screens
MOST
Most
Restores most Host or Port device parameters to factory defaults.
PAR#
Parameter Number
Navigates directly to a parameter.
PGDN
Page Down
Scrolls down to the next page of data lines on the Device Version information screen.
PGUP
Page Up
Scrolls up to the previous page of data lines on the Device Version information screen.
REF
Reference
Enters the speed reference for the Host Drive.
RESET
Reset
Resets the Process screen’s displayed monitoring items to the factory default monitoring items listed on
TEXT
Text
Edits user-definable text for the device selected.
TOP
Top
• Displays the top (most recent) fault, alarm or event in a queue.
• Scrolls to the top line of data on the Device Version information screen.
UPPER
Upper
Displays the upper 16 bits (bits 16…31) of a 32-bit Bit-type parameter.
VIEW
View
• Toggles between select screens and views.
• Displays the time stamp screen from a fault, alarm or event queue screen.
ZONES
Zones
Displays the Select Time Zone screen.
Soft Key Label
Name
Function
Displayed Information
Host PowerFlex Drive
750-Series
7-Class
Selected device icon and port number
✔
✔
Device name
(1)
(1) The displayed default device name is dependent on the host drive. The device name can be
changed, for example, to Host Drive as shown in the screens below. See
Drive/Peripheral Name on page 35
for details.
✔
✔
Rating text (volts, amps)
✔
✔
Drive catalog text
✔
not applicable
Firmware version and hardware series
(2)
(2) The firmware version and hardware series for a PowerFlex 750-Series drive can be shown using
HIM menu screens. For details, see
Checking Drive and Peripheral Firmware Revisions on page 47
✔
For PowerFlex 750-Series Drive
For PowerFlex 7-Class Drive
00
Stopped
0.00 Hz
AUTO
Host Drive
240V
4.2A
20G...D014
ESC
REF
TEXT
F
PAR#
00
Stopped
0.00 Hz
AUTO
Host Drive
240V
4.2A
Rev 3.002 Ser. A
ESC
REF
TEXT
F
PAR#