15 parameter reference, 3 table of attributes 650 – Lenze E84DSxxx User Manual
Page 650

15
Parameter reference
15.3
Table of attributes
650
Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
AINx: Input current
24546
5FE2
A
1
INTEGER_16
100
AINx: Output value
24542
5FDE
A
1
INTEGER_16
100
AINx: Configuration
24541
5FDD
A
1
UNSIGNED_8
1
DCB: Current
24539
5FDB
E
1
INTEGER_16
100
Fixed setpoint x (L_NSet_1 n-Fix)
24536
5FD8
A
15
INTEGER_16
100
MCTRL: Speed setpoint
24525
5FCD
E
1
INTEGER_32
1
MCTRL: Actual speed value
24524
5FCC
E
1
INTEGER_32
1
Motor voltage
24523
5FCB
E
1
UNSIGNED_16
1
DC-bus voltage
24522
5FCA
E
1
UNSIGNED_16
1
Motor current
24521
5FC9
E
1
UNSIGNED_16
100
Torque
24519
5FC7
A
2
INTEGER_32
100
Maximum torque
24518
5FC6
E
1
UNSIGNED_32
100
Output frequency
24517
5FC5
E
1
INTEGER_32
100
Appl.: Reference frequency C11
24516
5FC4
E
1
UNSIGNED_32
100
Heatsink temperature
24514
5FC2
E
1
INTEGER_16
1
Device utilisation (Ixt)
24511
5FBF
A
3
INTEGER_16
100
Thermal motor load (I²xt)
24509
5FBD
E
1
INTEGER_16
100
Vp speed controller
24505
5FB9
A
1
UNSIGNED_16
100
Ti speed controller
24504
5FB8
A
1
UNSIGNED_16
10
Imax/M controller gain
24502
5FB6
A
2
UNSIGNED_16
100
Reset time Imax/M controller
24501
5FB5
A
2
UNSIGNED_16
1
Vp current controller
24500
5FB4
E
1
UNSIGNED_16
100
Ti current controller
24499
5FB3
E
1
UNSIGNED_16
100
Override point of field weakening
24495
5FAF
E
1
INTEGER_16
1
Rated motor power
24494
5FAE
E
1
UNSIGNED_16
100
Motor rotor resistance
24493
5FAD
E
1
UNSIGNED_32
1
Motor rotor time constant
24492
5FAC
E
1
UNSIGNED_16
1
Motor stator resistance
24491
5FAB
E
1
UNSIGNED_32
1
Motor stator leakage inductance
24490
5FAA
E
1
UNSIGNED_16
100
Rated motor speed
24488
5FA8
E
1
UNSIGNED_16
1
Rated motor current
24487
5FA7
E
1
UNSIGNED_16
100
Rated motor frequency
24486
5FA6
E
1
UNSIGNED_16
1
Rated motor voltage
24485
5FA5
E
1
UNSIGNED_16
1
Motor cosine phi
24484
5FA4
E
1
UNSIGNED_8
100
Motor magnetising inductance
24483
5FA3
E
1
UNSIGNED_16
10
Power section ID
24482
5FA2
E
1
UNSIGNED_16
1
Motor magnetising current
24480
5FA0
E
1
UNSIGNED_16
100
Rated motor torque
24478
5F9E
E
1
UNSIGNED_32
100
Rated device current
24477
5F9D
E
1
UNSIGNED_16
10
Firmware version
24476
5F9C
E
1
VISIBLE_STRING
Firmware version
24475
5F9B
A
4
UNSIGNED_8
1
Add. acceleration time x
24474
5F9A
A
15
UNSIGNED_32
1000
Add. deceleration time x
24472
5F98
A
15
UNSIGNED_32
1000
Decel. time - quick stop
24470
5F96
E
1
UNSIGNED_32
1000
Auto-DCB: Hold time
24469
5F95
E
1
UNSIGNED_32
1000
DCB: Hold time
24468
5F94
E
1
UNSIGNED_32
1000
DIx: Polarity
24461
5F8D
E
1
UNSIGNED_16
DI 1/2 & 5/6: Function
24460
5F8C
A
2
UNSIGNED_8
1
DI 3/4 DO 1/2: Function
24459
5F8B
E
1
UNSIGNED_8
1
DOx: Inversion
24457
5F89
E
1
UNSIGNED_8
Motor overload threshold (I²xt)
24455
5F87
E
1
INTEGER_16
100
Code
Name
Index
Data
Access
dec
hex
DS
DA
DT
Factor
R
W
CINH