C00586 | resp. to encoder open circuit, C00588 | resp. to max. speed at switching freq, C00590 | resp. to switching frequency red – Lenze E84DSxxx User Manual
Page 565: C00586, Is activated, C00590, C00588, 15 parameter reference

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
565
15
Parameter reference
15.2
Parameter list | C00586
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00586
C00588
C00590
Parameter | Name:
C00586 | Resp. to encoder open circuit
Data type: UNSIGNED_8
Index: 23989
d
= 5DB5
h
Response to encoder feedback system failure or encoder feedback system track failure due to open circuit
Selection list
(Lenze setting printed in bold)
0 No Reaction
1 Fault
5 Warning
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00588 | Resp. to max. speed at switching freq.
Data type: UNSIGNED_8
Index: 23987
d
= 5DB3
h
Response if the maximum speed for the set inverter switching frequency is reached (
Selection list
(Lenze setting printed in bold)
0 No Reaction
1 Fault
5 Warning
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00590 | Resp. to switching frequency red.
Data type: UNSIGNED_8
Index: 23985
d
= 5DB1
h
Response to reduction of the inverter switching frequency (
Selection list
(Lenze setting printed in bold)
0 No Reaction
1 Fault
5 Warning
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1