FoamLogix, Model 2.1A and 1.7AHP Class “A”

Electronic Foam Proportioning Systems

53

USER CALIBRATION

The complete Hale FoamLogix Systems; foam pump

and motor assembly, control unit and flow sensor, is

tested at the factory before shipping to the installer.

If the Hale FoamLogix system is properly installed,

further calibration IS NOT necessary until delivery to

customer.

The system permits easy checking of component

calibration to assure accurate operation. The

calibration process verifies component calibration

and allows adjustments to the flow sensor and

feedback sensor display readings, to allow for

variations in apparatus piping configurations and

end user selected foam concentrate.

Default values for simulated flow and foam

concentrate injection rate may be set to end user

specifications while in the calibration mode.

Note: The Hale FoamLogix system is calibrated

at the factory to U.S. measurement (GPM, PSI,

GALLONS, etc.) units. The system may be set

to Metric units. (See heading “English to Metric

Units” on page 58.) However, the same unit

of measurement must be used throughout the

calibration process to ensure proper proportioning

by the system.

Recalibration of the system may be required ONLY

after major repairs or component changes are made

to the Hale FoamLogix foam system. Different

viscosity foam concentrates may also required

recalibration.

ENTERING PASSWORDS

Entering passwords is accomplished using the

control unit function buttons.

To enter passwords, press and hold the

DIS PLAY

button. The display shows

PASS, then clears. While

continuing to hold the display button press the  or

buttons sequentially to enter the password. See

Table 25: “Password Sequence.”

Mode

Password Sequence

User Calibration

   

Restore Factory Defaults

   

Table 25: Password Sequence

RESTORE FACTORY DEFAULTS

To return to the factory default values, enter the

restore factory values password (    ) as

previously described.

Once the password is entered correctly the unit

displays

FAC and returns to normal operation.

Factory default values:

Simulated Flow.... 150 GPM (568 LPM) %
FOAM .............. 0.5% Class “A”

Also see Figure 26: “Display - Password and

Calibration Modes” on page 54.

CALIBRATION

To enter calibration password press and hold

1

the SELECT DISPLAY button (

i). The display

shows PASS, then clears.

While holding

2

i pressed, enter the calibra tion

password ().

The display shows

3

CALL for several seconds,

followed by

L (or O when display is set to

metric). (See Figure 26: “Display - Password

and Calibra tion Modes” on page 54.)

The

FLOW LED (Water Flow sensor

Calibration) also illuminates. (See Figure

27: “Display - Flow Sensor Calibration” on

page 54.)