FoamLogix, Model 2.1A and 1.7AHP Class “A”

Electronic Foam Proportioning Systems

42

The inlet connection of the check valve/ injector

fitting uses a 1/2” NPT female thread.

Foam Concentrate Injection Hose

Connect a hose from the foam pump inject port

to the inlet of the check valve injector fitting.

(See Figure 18: “Injection and Bypass Hose

Connection”)

The hose and fittings from the INJECT port to the

check valve injector fitting should have minimum

1/2” (13 mm) outside diameter and be rated at 500

PSI (34 BAR) working pres sure (Aeroquip 2580-10

or equal).

Bypass Hose Connection

A bypass valve is mounted on the discharge of the

foam pump. The bypass handle must be accessible

by the pump operator during normal operations.

The bypass is a 3-way directional valve. Determine

which port is the INJECT port and which port is the

BYPASS. (See Figure 18: “Injection and Bypass

Hose Connection”)

Bypass hose connections are 1/2”. Hose fittings

compatible with all foam concentrates must be

provided. The hose from the BY PASS port is

plumbed to the atmosphere.

This hose is used for calibrating the foam pump,

pumping the concentrate into a con tainer to empty

the foam tank or to assist in priming of the foam

pump. The hose from the BYPASS port must be

long enough to reach a container outside the truck.

Bypass Valve

Inject Hose Connection

(1/2” Compression Fitting)

Bypass Hose Connection

(1/2” Compression Fitting)

Foam Concentrate Inlet

(1/2” Hose Barb)

Foam Concentrate

Shut Off Valve

(Shown in OPEN position - rotate 90

o

to CLOSE)

Foam Concentrate

Strainer

Foam Pump

Figure 18: Injection and Bypass Hose Connection