There are no user serviceable parts inside Hale
Foam system electrical/electronic components.
Opening of the distribution box or control unit
voids the warranty.
❑
Use mounting hardware that is compatible with
all foam concentrates to be used in the system.
Use washers, lock washers and cap screws
made of brass or 300 series stainless steel.
❑
When making wire splice connections, make
sure they are properly insulated and sealed using
an adhesive filled heat shrink tubing.
❑
ALWAYS connect the primary positive power
lead from the terminal block to the master switch
terminal or the positive battery terminal.
Use a minimum 8 AWG type SGX (SAE J1127)
chemical resistant battery cable and protect with
wire loom.
❑
Prevent corrosion of power and ground
connections by sealing these connections with
silicone sealant provided.
❑
Prevent possible short circuit by using the rubber
boot provided to insulate the primary power
connection at the Hale FoamLogix distribution
box.