beautypg.com

Class1 Engine status OEM menu User Manual

Oem m

background image

1

To enter the OEM Menu, the engine must be at less than 900 RPM

Press the switches in this sequence.

SELECT

:

SILENCE

:

SELECT

:

SELECT

:

MENU

Scroll through menu items by pressing the

MENU

switch.

Select items from the menu by pressing the

SELECT

switch.

After Selection, change items by pressing the

SELECT

switch.

Save information and exit from the menu by pressing the

SILENCE

switch unless noted.

* You must save any changed item before moving on in the menu!

MENU

CLR HRS

SELECT

clk: PTO

PTO Clock

Press the select switch first and then the silence switch, hold both for 1 second and

then release select first and then silence to save data

SELECT

clk: USER

User Clock

Press the select switch first and then the silence switch, hold both for 1 second and

then release select first and then silence to save data

MENU

SVC TIME

SELECT

Time Interval digits displayed on Engine RPM
Change hours by depressing the

SELECT

switch

Direction changes each time the key is pressed.
press

SILENCE

to update service interval (0-9999 hrs)

MENU

LV-ALM: (Y / N)

SELECT

enable or disable the low voltage alarm

MENU

AUX INP

SELECT

-AUX- IN-

configure message for this input that will be displayed when it is active.

SELECT

selects character to change, indicated by flashing cursor.

SILENCE

scroll letters

(A-Z blank a-z 0-9)

Press the select switch first and then the silence switch, hold both for 1 second and

then release select first and then silence to save data

MENU

ALARM: (Y / N)

SELECT

enable or disable the aux input alarm

MENU

AUX HRS

SELECT

-AUX- HR-

configure message for this input that will be displayed when it is active.

SELECT

selects character to change, indicated by flashing cursor.

SILENCE

scroll letters

(A-Z blank a-z 0-9)

Press the select switch first and then the silence switch, hold both for 1 second and

then release select first and then silence to save data

MENU

CHG LOGO

SELECT

-CLASS1-

configure message that will be displayed in the Message Center.

SELECT

selects character to change, indicated by flashing cursor.

SILENCE

scroll letters

(A-Z blank a-z 0-9)

Press the select switch first and then the silence switch, hold both for 1 second and

then release select first and then silence to save data

MENU

DEFAULTS

SELECT

returns ESC to default configuration.

OEM M

ENU