Konica Minolta bizhub PRO C6500P User Manual
Page 152
144
Chapter 7—Color Workflow
12.
Place the calibration chart on a flat surface, and scan the chart
with the Eye-One spectrophotometer, as follows:
•
Press and hold the button on the side of the
spectrophotometer, and align the head with the cyan
arrow’s tip. The arrow is to the left of the cyan column on
the calibration chart. Its tip intersects the semi-dotted line.
•
Wait for the spectrophotometer to beep before sweeping it
across the cyan column.
•
A check mark appears over the cyan icon in the Color
Calibration window.
13.
Repeat the scanning for the magenta, yellow and black
column.
If at any stage the scanning has not been completed properly,
click
Reset
and scan again.
14.
Click
Next
when calibration is complete.
This manual is related to the following products: