BATCH OPERATION

Symptom

Probable Cause

Possible Solution

Activated batch
appears to be
running through
batches rapidly.

Batch Activated with Old Start Date. For
example, today is 4/26/00, You have a
repeating batch programmed to start on
4/24/00). The display will show the 'run-
through' of all batches between start the
start day and time and today.

Change Batch start-time to current or future
date/time.

Repeating Batch
will not start.

Batch duration is set to 0 hours and 0
minutes.

Duration must be greater than 0 minutes for batch
to activate.

CALIBRATION

Symptom

Probable Cause

Possible Solution

Message:
{Terminated /
Press any key}
appears during
Calibration.

Stroke setting adjusted while
Calibration session was active.

Do not touch the stroke adjustment
mechanism while a Calibration session is
active.

UNITS

Symptom

Probable Cause

Possible Solution

Units do not
increment with
change in %.

Unit not properly calibrated. Calibration
beyond display resolution.

Re-calibrate to value within display range.
Change number format to give additional
precision.

MISCELLANEOUS

Symptom

Probable Cause

Possible Solution

Incoming Power un-reliable

DLC should have separate branch circuit taken
from main. Re-wire.
Consider surge-suppression.

Voltage failure
message displayed

DLC factory configured for operating
voltage other than input.

DLC must run under Factory configured
operating voltage. Locate source of correct
voltage and re-wire.

Power failure
message displayed.

PULSAR motor running at time of power
loss.

Turn PULSAR motor off before powering DLC
down.

ENCODER ERROR

Symptom

Probable Cause

Possible Solution

DLC-XP to DLC-RC encoder wiring
incorrect.

Correct wiring. Refer to section 5-Installation:
Control Connections.

DLC-XP to DLC-RC control wiring
incorrect.

Correct wiring. Refer to section 5-
Installation:Control Connections.

Message:
{ENCODER
ERROR /
PRESS ENTER}
displays during
zero calibration.

Encoder defective.

Contact Technical Services.

Refer to next section - Encoder Diagnostics