Pulsafeeder Pulsar DLC XP RC User Manual
Page 36

32
You can access a sub-menu from the above screen by pressing [ENTER] if a circuit failure has
occurred. The lower level menus show more descriptive circuit information. The DLC – XP
performs a self-test at power-up. The values in the menus shown below are updated during
power-up. Use [UP] to scroll between sub-menus.
CIRCUIT FAILURE
RAM: OK
or
CIRCUIT FAILURE
RAM: FAIL
CIRCUIT FAILURE
EEPROM: OK
or
CIRCUIT FAILURE
EEPROM: FAIL
CIRCUIT FAILURE
MOTOR: OK
or
CIRCUIT FAILURE
MOTOR: FAIL
j) Use [UP] to scroll to the next sub-menu. The total pump operating time is displayed in this
diagnostic sub-menu. If a failure is detected in one of the other diagnostic sub-menus, by
pressing [ENTER] the user is prompted to reset the total run time or continue counting the total
operating hours.
DIAG MENU 10/11
RUN :XXX HRS
Press
[ENTER]
RESET RUN TIME
YES
k) Use [UP] to scroll to the next sub-menu. The NEMA 7 version of the DLC (XP/RC) does not
have a tachometer for a stroke counting capability.
DIAG MENU 11/11
STROKES: N/A
3. Pressing [ENTER] on the screens depicted in steps a, b, c, d, e, and g above will display the time and
date of the failure or more descriptive information.
POWER FAILURE
13:27 4/26/00
4. Press [ENTER] again, and the user is prompted to clear the failure. Depending upon the type of
failure diagnosed, the user may want to take other steps before clearing the failure and restarting the
pump. If so, press [ENTER] to keep the error date and time stamp. Otherwise, use [UP] to scroll to
"YES" and press [ENTER]. The DLC – XP will return to a normal condition.
POWER FAILURE
CLEAR? NO
If more than one failure occurred, repeat steps 3 and 4 above for each sub-menu that indicates a
failure was detected.