9. Specifications
Turndown Ratio ......................... up to 10:1 (application dependent)
Accuracy .................................... No added inaccuracy to pump flow.
Resolution ................................. 0.1%; up to four digits on units of flow.
Response ................................... 1% per second
Temperature .............................. 18° C to 40° C (0° F to 104° F) Operation
18° C to 60° C (0° F to 140° F) Storage
High Voltage Inputs
Line Power (J1) ......................... (Factory Configured):
115 VAC +/- 10%, 60 Hz, 10 Amp max.
115 VAC +/- 10%, 50 Hz, 10 Amp max.
230 VAC +/- 10%, 60 Hz, 5 Amp max.
230 VAC +/- 10%, 50 Hz, 5 Amp max.
High Voltage Outputs
Alarm Relay (J2) ...................... 1 Amp at rated Line Voltage (Fused)
Pump Motor (J3) ....................... 7 Amps at 115 VAC
3.5 Amps at 230 VAC
Must be rated at line Voltage
Low Voltage Inputs
Analog Input (J4-1, J4-2)
Range ..................... 0 to 25mA / 0 to 5volts
Minimum Span....... 2mA / 0.4 volts
Fuse ........................ 50mA
Surge Protection ..... 7.4 Joules
Isolation.................. 500volts from all other I/O and ground
Modes..................... Split Ranging / Reverse Acting / Ratio
PULSAlarm (J4-3, J4-4)
Type ....................... Dry Contact (Do not apply powered signal)
Modes..................... Normally Open / Normally Closed
Digital (J4-5, J4-6)
Type ...................... Dry Contact (Do not apply powered signal)
Isolation:................. Not isolated from PULSAlarm or motor thermostat. 500 volts from
all other inputs, outputs and ground.
Modes .................... Normally Open / Normally Closed