Factory default values, Retrieval of setup information, Special key press access – Pulsafeeder MPC Vector User Manual
Page 57
51
15. Factory Default Values
Parameter
Factory Set Value
Digital Input #1
INACTIVE, normally closed
Digital Input #2
INACTIVE, normally closed
Analog Input #1
INACTIVE
Analog Input #2
INACTIVE
Digital Output #1
ON/OFF indication, normally closed
Digital Output #2
AUTO/MANUAL Indication, normally closed
Digital Output #3
ALARM Indication, normally closed
Security Code
Default = 0000
Language
ENGLISH
MODE
Local (Manual)
UNITS
GPM (gallons per minute)
16. Retrieval of Setup Information
Users can access the
system SETUP : INFORMATION
menu, which will list the following data,
this may be helpful in troubleshooting:
Controller software revisions
Pump serial number
MPC VECTOR model number
Pump maximum flow and PulsaGuard minimum flow setpoint
Pump maximum speed and PulsaGuard minimum current setpoint
17. Special Key Press Access
In This SCREEN
Press MENU and ENTER at the same time to:
MENU
ANAL OG I/O
Show calibration and RAW data for analog inputs
MENU
DIGI TAL I/ O
Feature not available
Press the MENU key to exit from any of these special screens.