Pulsafeeder MPC Vector User Manual
Page 49
43
NON-FATAL ERRORS: The pump and controller can still be run while these conditions exist.
The Red LED will flash and the error will flash on the screen. The Red LED and error message
will cease once the error condition has been corrected.
SOFT WAR E F au lt
Erro r = ## ##
Software related problem, record error number and consult
factory
Hard war e f au lt
Erro r = ## ##
Hardware related problem, record error number and consult
factory
CONS ULT fa ct or y
Erro r = ## ##
Unidentified error, record error number and consult factory
USER NOTIFICATIONS: These are errors in setup or calibration. They will display on the
screen for several seconds. They can be corrected by properly completing the procedure
involved.
Cann ot acc es s
With mo tor o n
User is trying to change a setting that cannot be changed
while the pump is running
Curr ent de lt a
Out of ran ge
Not enough difference between high and low signals during
an analog input signal calibration (min 3 mA)
No r emo te
Cont rol
User is trying to activate the AUTO mode, but there is no
remote input (mA signal or remote on/off) to the controller
.
For unlisted or numbered error codes, consult the factory for assistance.