11. Alarm and Error Messages

If a fatal error has occurred while in Operational Mode, the error will flash on the screen and the Red LED
lamp will also flash. The menus can still be accessed by pressing the menu key. This allows the user to try
and fix the source of the error if possible.

11.1 Error Log

As each error occurs an entry is saved in an Error Log. You may view the four most recent errors as well as the
current status through the System Setup Menus.

11.1.1

Viewing the Error Log

1. The starting display will be:

S E T P T

X X . X X X

F L O W

X X . X X X

2. Press the MENU key

- M E N U -

C A L I B R A T I O N

3. Press the UP arrow key

- M E N U -

S Y S T E M S E T U P

4. Press the ENTER key

S Y S T E M S E T U P

S T A T U S

5. Press the ENTER key again to view the current status

- - N O - -

- - E R R O R - -

6. Press the DOWN key to view the most recent system error

A L A R M

L E A K D E T E C T

7. Continue pressing the DOWN key to scroll through the 4 most recent errors.

8. Press the MENU key at any time, while viewing either current status or Log entries, to exit the Error

Log.

Once you see ‘NO ERROR’ in the Error Log (the screens AFTER current status) there will be no errors
in any of the subsequent positions. If the pump turns off for any reason check the Error Log to see any
messages that were reported. Some errors may clear themselves from the screen, but the entry will still
be in the Error Log.