Pulsafeeder MPC Vector User Manual

Page 35

background image

29

9. Press the ENTER key once more to accept the calibration value

A N A L O G O U T P U T

C A L I B R A T E D

10. Analog output signal calibration is complete

11. Press the MENU key three times to exit back to the main operating screen

If you receive the following message:

C U R R E N T D E L T A

O U T O F R A N G E

This indicates that the output current for 0% speed has been set greater than or equal to the output current
setting for 100% speed. Repeat the process and ensure that the 0% calibrated signal is set to a value lower
than the 100% calibrated signal.