8.2.2 “DRY” Analog Input Calibration

(keypad only, no signal present)

1. The starting display will be:

S E T P T

X X . X X X

F L O W

X X . X X X

2. Press the MENU key

- M E N U -

C A L I B R A T I O N

3. Press the ENTER key

C A L I B R A T I O N

P U M P F L O W

4. Press the UP arrow key twice, to access the analog input calibration

C A L I B R A T I O N

A N A L O G I N P U T

5. Press the ENTER key

A N A L O G I N P U T

W E T C A L

6. Press the UP or DOWN key

A N A L O G I N P U T

D R Y C A L

7. Press the ENTER key to access the DRY Pump Flow Calibration routine for ANALOG Flow Meters. A

blinking cursor will show you that you are adjusting the Current (mA).

M I N S E T P T 0 . 0 M A
F L O W : 0 . 0 0 G P M

8. Press the UP and/or DOWN keys to adjust the Current setpoint.

M I N S E T P T 4 . 0 M A
F L O W : 0 . 0 0 G P M

9. Press the ENTER key to accept this setpoint. The Cursor will now blink on the second line, indicating that

the 4mA Flow is the active field. Press the UP and/or DOWN keys to adjust the Flow setpoint.

M I N S E T P T 4 . 0 M A
F L O W : 0 . 0 0 G P M

10. Press the ENTER key to access the MAX setpoint values. The cursor will blink on the top line indicating

that the Current setpoint may be adjusted.

M A X S E T P T 1 6 . 0 M A
F L O W : 4 . 0 0 G P M