beautypg.com

Resetting statistics counters, Menu, To reset switch (system) counters – Allied Telesis AT-S20 User Manual

Page 115: Select zero all statistics on the entire system, Resetting statistics counters -5, To reset switch (system) counters -5, 5hvhwwlqj#6wdwlvwlfv#&rxqwhuv

background image

AT-S20 User’s Guide

7-5

5HVHWWLQJ#6WDWLVWLFV#&RXQWHUV

0HQX1

Ethernet statistics> Zero all statistics

on the entire system

You reset the statistics counters because:

The counters no longer reflect the current information.

For example, disabling a port to fix a problem does not reset
its counters. After the error clears and you manually re-enable
the port, you may want its statistics to accumulate from a fresh
start. Otherwise, the counters and the graph not only still
reflect information associated with the error condition; the
counters continue to increment from the wrong baseline.

As each frame type reaches the maximum of 2

32

(over 4

billion), the statistics for that frame type resets to zero. Once
this happens, the counters and graph become inaccurately
skewed.

7R#5HVHW#6ZLWFK

+6\VWHP,

&RXQWHUV

1. Select

Ethernet Statistics

from the Main Menu to display

the Receive Statistics Graph.

2. Select

Zero all statistics on the entire system

.

Both Receive and Transmit counters and graphs are reset to zero.