Restoring the default configuration – Allied Telesis AT-S94 User Manual
Page 207

System Utilities
Page 207
Restoring the Default Configuration
The Reset to Factory Defaults function restores the Configuration file to factory defaults during device reset. When
this option is not selected, the device maintains the current Configuration file.
To restore the default system configuration:
1.
Click Utilities > System Utilities. The System Utilities Page opens:
Figure 144:System Utilities Page
The System Utilities Page contains the following fields:
•
Reboot Switch After Resetting to Defaults — Performs reboot after the reset. The possible field values
are:
–
Checked — System restarts after the Configuration File is restored to the factory defaults.
–
Unchecked — After the Configuration File is restored to the factory defaults, the system remains in
session.
•
Unit No. — Indicates the unit number.
•
Active Image — Indicates the current image file.
•
Software Version — Displays the current software release.
•
After Reset — The Image file that is active after the device is reset. The possible field values are:
–
Image 1 — Activates Image file 1 after the device is reset.
–
Image 2 — Activates Image file 2 after the device is reset.
To reset the configuration file to defaults without rebooting the device:
•
Click Apply in the Reset to Factory Defaults section.