x610 Series Layer 3 Gigabit Ethernet Switches Installation Guide

49

Redundant Power Supplies

The Redundant Power Supply connector on an x610 Series switch rear

panel can connect to an optional Redundant Power Supply (RPS), the

AT-RPS3000. The RPS can provide power to the switch in the event of a

failure of the switch’s internal power supply.
The AT-RPS3000 has slots for two power supply modules. Either the

AT-PWR800 (800W) or AT-PWR1200 (1200W) power supply modules

can be installed in the RPS.

Warning

Do not hot swap the power supply modules. It is not necessary to

power down the RPS before you remove or swap a power supply

module. However, always disconnect the AC cord before the power

supply module is removed and ensure the power supply module is

correctly installed before reconnecting the AC cord.

When fully populated, the RPS can support up to four x610 switches

simultaneously, depending on the switches configuration. The RPS can

backup one high-power consumption switch or two low-power

consumption switches with each power supply module. The 24 port

switches are considered low-power consumption switches while the 48

port switches are considered high-power consumption switches. The RPS

is not able to identify if the attached switch is a high-power consumption

switch or a low-power consumption switch.
The RPS has four connectors on the rear panel, as shown in Figure 24.

Connectors 1 and 2 supply power from power supply module A, the right

side module, and connectors 3 and 4 supply power from power supply

module B, the left side module.

Figure 24. Connectors on RPS

Connectors 1 and 3 supply system power only and connectors 2 and 4

supply system power and extra PoE power. A switch connected to

connector 2 will receive extra PoE power only from power supply module

A and a switch connected to connector 4 will receive extra PoE power only

from power supply module B.