beautypg.com

Outback Power Systems MATE2 System Controller and Display Installation and User Manual User Manual

Page 88

background image

88

ADV/MATE/AGS/LS-----------------

load stop 0 kw

DOWN UP INC DEC

ADV/MATE/AGS/LS----------------

load stop 1 min

delay
DOWN UP INC DEC

ADV/MATE/AGS/LS---------------

end of the LOAD

START menu
UP TOP AGS

Load Stop Delay

Load Stop KW

An AGS stop command will be issued when the

total AC load of all the FXs connected to the

MATE falls below this setting for the amount of

time set with load stop delay (next screen) as long

as the generator was started due to Load Start.

This setting excludes any FX charger current

for its AC load calculation. The setting can be

changed using the and soft keys.

Pressing the soft key leads to the load

stop delay screen.

This setting is the delay time the total system AC

load must remain below the Load Stop kw before

the generator is stopped. It is adjustable from 1 to

240 minutes using the and keys.

Pressing the soft key leads to the end of

the VOLTAGE START menu screen.

Pressing the soft key returns the ADV/

MATE/AGS/PG2 screen

This manual is related to the following products: