P2000/MSA2000—Volume name
◦
P9000/XP—Emulation type and LDKC:CU:LDEV (for example, HP OPEN-V-CVS (00:04:3F))
•
Array Disk Type—Array disk type
•
Array Name
P4000—Management group name
◦
◦
3PAR—Array display name
◦
P6000 EVA—Array display name
◦
P2000/MSA2000—System name
◦
P9000/XP—Array serial number
•
Array Type—HP array type
•
Array Disk Total Capacity—Total amount of storage available to the datastore
•
Array Disk Allocated Capacity—Size of the virtual disk on the array
•
Array Disk Provisioned—Whether the virtual disk uses thick or thin provisioning
•
Array Controller—Controller used for this path
•
Array Port—Storage array's port identifier used for this path
•
Host Group
P4000—Name configured for the host's IQN in the management console
◦
◦
3PAR—Name of the host object containing the host WWN for this path
◦
P6000 EVA—Name of the host object containing the host WWN for this path
◦
P2000/MSA2000—Nickname of the host with the host WWN for this path
◦
P9000/XP—Name of the host group containing the HBA WWN on the array port for
this path
•
Host Access
P4000—Host access level assigned to the presentation of the disk to the host (for example,
READ/WRITE or READ-ONLY)
◦
◦
3PAR—N/A. 3PAR storage volumes operate in a read-only/read-write configuration.
◦
P6000 EVA—Host access level assigned to the presentation of the disk to the host (for
example, READ/WRITE or READ-ONLY)
◦
P2000/MSA2000—Access setting for volume mapping (for example, READ/WRITE or
READ-ONLY)
◦
P9000/XP—Host access level assigned to the volume
NOTE:
The P9000 or XP array does not allow host access to be specified on a per-host
or per-path basis.
•
Host Mode
P4000—Not applicable
◦
◦
3PAR—Not applicable
Using the Storage Module for vCenter