beautypg.com

HP OneView for VMware vCenter User Manual

Page 57

background image

P2000/MSA2000—Volume name

P9000/XP—Emulation type and LDKC:CU:LDEV (for example, HP OPEN-V-CVS (00:04:3F))

Array Disk Type—Array disk type

Array Name

P4000—Management group name

3PAR—Array display name

P6000 EVA—Array display name

P2000/MSA2000—System name

P9000/XP—Array serial number

Array Type—HP array type

Array Disk Total Capacity—Total amount of storage available to the datastore

Array Disk Allocated Capacity—Size of the virtual disk on the array

Array Disk Provisioned—Whether the virtual disk uses thick or thin provisioning

Array Controller—Controller used for this path

Array Port—Storage array's port identifier used for this path

Host Group

P4000—Name configured for the host's IQN in the management console

3PAR—Name of the host object containing the host WWN for this path

P6000 EVA—Name of the host object containing the host WWN for this path

P2000/MSA2000—Nickname of the host with the host WWN for this path

P9000/XP—Name of the host group containing the HBA WWN on the array port for
this path

Host Access

P4000—Host access level assigned to the presentation of the disk to the host (for example,
READ/WRITE or READ-ONLY)

3PAR—N/A. 3PAR storage volumes operate in a read-only/read-write configuration.

P6000 EVA—Host access level assigned to the presentation of the disk to the host (for
example, READ/WRITE or READ-ONLY)

P2000/MSA2000—Access setting for volume mapping (for example, READ/WRITE or
READ-ONLY)

P9000/XP—Host access level assigned to the volume

NOTE:

The P9000 or XP array does not allow host access to be specified on a per-host

or per-path basis.

Host Mode

P4000—Not applicable

3PAR—Not applicable

Using the Storage Module for vCenter

57