Critical events

Event ID

Vertical mapping failure. Scanner was unable to detect vertical target
during calibration.

0x267

Horizontal axis did not reach appropriate position within the time limits.
Retry command.

0x268

Horizontal axis did not reach appropriate position.

0x269

Horizontal axis did not reach the home position.

0x26a

The value of the horizontal encoder did not change during the self test.

0x26b

The value of the horizontal encoder did not change during the self test

0x26c

Horizontal mapping failure. Scanner was unable to detect horizontal
target during calibration.

0x26d

This is only a warning that the temperature in the library exceeds the
normal operational temperature (98.6F).

0x26e

Gripper hardware failure, lost grip of tape.

0x270

SCSI interface failed to start.

0x2c0

Initialization failed on partition $partition.

0x2c1

Parse error

0x2c2

Missing HBA for partition $partition

0x2c3

Unable to connect to cabinet controller from $ip, $page.

0x3a0

Lost connection to cabinet controller from $ip, $page

0x3a1

Cabinet controller unable to start new thread for command $cmd.

0x3a4

Error Response from cabinet controller — Cannot find a cabinet.

0x3a5

Unable to communicate with cabinet task process for command
$pipefailcmd.

0x3a6

Error Response from cabinet controller, webpage $page subroutine
$swsub, cabd response $response

0x3d0

Unable to connect to cabinet controller for cabinet $fname.

0x4a0

Lost connection to cabinet controller for cabinet $fname.

0x4a1

HP Interface Manager not present on frame $fname

0x4a2

Event monitor failed to respond for cabinet $fname.

0x4a3

Corrupted database - Need to Restore Library Database to Factory Set-
tings (via front panel).

0x4a5

Smart media for cabinet $framename needs to be replaced. There are
$badblocks badblocks in zone $zone.

0x700

CLM $name sensor needs attention, status $status

0xb01

Event reporting