HP ESL E-series Tape Libraries User Manual
Page 148

Critical events
Event ID
Vertical mapping failure. Scanner was unable to detect vertical target
during calibration.
0x267
Horizontal axis did not reach appropriate position within the time limits.
Retry command.
0x268
Horizontal axis did not reach appropriate position.
0x269
Horizontal axis did not reach the home position.
0x26a
The value of the horizontal encoder did not change during the self test.
0x26b
The value of the horizontal encoder did not change during the self test
0x26c
Horizontal mapping failure. Scanner was unable to detect horizontal
target during calibration.
0x26d
This is only a warning that the temperature in the library exceeds the
normal operational temperature (98.6F).
0x26e
Gripper hardware failure, lost grip of tape.
0x270
SCSI interface failed to start.
0x2c0
Initialization failed on partition $partition.
0x2c1
Parse error
0x2c2
Missing HBA for partition $partition
0x2c3
Unable to connect to cabinet controller from $ip, $page.
0x3a0
Lost connection to cabinet controller from $ip, $page
0x3a1
Cabinet controller unable to start new thread for command $cmd.
0x3a4
Error Response from cabinet controller — Cannot find a cabinet.
0x3a5
Unable to communicate with cabinet task process for command
$pipefailcmd.
0x3a6
Error Response from cabinet controller, webpage $page subroutine
$swsub, cabd response $response
0x3d0
Unable to connect to cabinet controller for cabinet $fname.
0x4a0
Lost connection to cabinet controller for cabinet $fname.
0x4a1
HP Interface Manager not present on frame $fname
0x4a2
Event monitor failed to respond for cabinet $fname.
0x4a3
Corrupted database - Need to Restore Library Database to Factory Set-
tings (via front panel).
0x4a5
Smart media for cabinet $framename needs to be replaced. There are
$badblocks badblocks in zone $zone.
0x700
CLM $name sensor needs attention, status $status
0xb01
Event reporting
148