Message name / description

ASCQ

ASC

Sense
key

CONFIGURATION SETTINGS CORRUPTED
Reconfigure the library. Run the Calibrate Cabinet Test from the OCP.

0A

80

4

LOW POWER ERROR
Check power connections and power supplies.

0F

80

4

PICKER HARDWARE FAILURE

Remove any obstructions.

Run the Robotics Self Test from the OCP.

See

Table
22

81

4

ROTARY HARDWARE FAILURE

Remove any obstructions.

Run the Robotics Self Test from the OCP.

See

Table
22

82

4

EXTENSION HARDWARE FAILURE

Remove any obstructions.

Run the Robotics Self Test from the OCP.

See

Table
22

83

4

VERTICAL HARDWARE FAILURE

Remove any obstructions.

Run the Robotics Self Test from the OCP.

See

Table
22

84

4

HORIZONTAL HARDWARE FAILURE

Remove any obstructions.

Run the Robotics Self Test from the OCP.

See

Table
22

85

4

DEPTH HARDWARE FAILURE

Remove any obstructions.

Run the Robotics Self Test from the OCP.

See

Table
22

87

4

WARNING SAFE TEMPERATURE EXCEEDED
This is a warning that the temperature in the library exceeds the normal
operational temperature 40

o

C (104

o

F).

00

88

4

MAXIMUM TEMPERATURE EXCEEDED
The robot in the overheated cabinet turns off and remains off until the
temperature returns to an acceptable level. For LTO, the acceptable level
is 52

o

C (127

o

F); for SDLT, the acceptable level is 49

o

C (120

o

F).

Check whether the air filters need to be replaced.

Check for fan failure.

Lower the ambient temperature.

01

88

4

VISION HARDWARE FAILURE
Vision internal failure.

00–FF

89

4

CALIBRATION FAILURE
Check slots, cartridges, targets, and all internal elements. Verify that the
panels are properly seated and that doors are closed.

02

8A

4