HP ESL E-series Tape Libraries User Manual
Page 136

Message name / description
ASCQ
ASC
Sense
key
LOGICAL UNIT TURNED ON-LINE
Through the menu options, bring the library on-line. This message is
informational only; no action is required.
09
80
6
LOGICAL UNIT TAKEN OFFLINE
Library was taken off-line through the remote web management or OCP.
09
80
6
DATA TRANSFER CHANGED
A drive has been inserted/removed into the system. Use “Read Element
Status” to determine status of drives.
0E
80
6
MODE PARAMETERS CHANGED
Mode parameters may have changed due to another host issuing a Mode
Select command.
01
2A
6
MAGAZINE INSERTED
A tape cartridge magazine has been inserted.
13
3B
6
LOGICAL UNIT COMMUNICATION FAILURE
Check cables. Ensure library unit is powered on. Retry command.
00
08
B
LIBRARY COMMUNICATION TIME-OUT
Internal communications not responding. Retry command. Check the
following internal cable connections: Ethernet cable, umbilical cable,
robotics controller, cabinet controller.
01
08
B
INCOMPATIBLE MEDIA
An attempt was made to move media to a destination element that is
incapable of receiving it. Make sure you are using the correct media
and that it is labeled with the correct barcode.
00
30
B
SCSI MESSAGE ERROR
Detected message error in message processing on the SCSI BUS.
•
Verify termination.
•
Verify SCSI cable connections.
•
Check host status.
•
Restart system.
00
43
B
SCSI PARITY ERROR
SCSI Parity Error detected.
•
Verify termination.
•
Verify SCSI cable connections and cable length.
•
Check host status.
•
Restart the system.
00
47
B
INITIATOR DETECTED ERROR MESSAGE RECEIVED
00
48
B
Sense data values
136