Critical events
Event ID
CLM hardware failed due to robotics FPGA failure.
0x248
The hardware home position is drifting.
0x249
CLM hardware failure. Scanner was unable to detect optical target during
calibration.
0x24a
While pushing a cartridge into a bin or drive, the extension axis never
made contact with any object.
0x24b
The sensor was occluded unexpectedly during calibration, inventory or
pick/place.
0x24c
CLM hardware failure. Electronics necessary for hardware to function is
not present.
0x24d
Gripper axis code internal failure.
0x24e
Extension axis code internal failure (cabinet $framenum).
0x24f
Vertical axis code internal failure.
0x250
Horizontal axis code internal failure.
0x251
A data transfer error or a data storage error was received during the
firmware upgrade.
0x252
Calibration failed for address $addr (target not found)
0x257
Extension axis did not reach appropriate position.
0x258
The extension axis is obstructed.
0x259
The extension axis was unable to move to commanded position
0x25a
The extension axis did not reach the home position.
0x25b
The value of the extension encoder did not change during the self test.
0x25d
The value of the extension encoder did not change during the self test.
0x25e
During calibration or pushing into a drive, the extension never reached
its intended force.
0x25f
During calibration or pushing into a drive, the extension never made
contact with any object.
0x260
The CIG sensor was occluded unexpectedly during calibration, inventory
or pick/place.
0x261
Vertical axis did not reach appropriate position within the time limits.
0x262
Vertical axis did not reach appropriate position.
0x263
Vertical axis did not reach the home position.
0x264
The value of the vertical encoder did not change during the self test.
0x265
The value of the vertical encoder did not change during the self test.
0x266