Examples – HP XP P9500 Storage User Manual
Page 79
Description
Operand
internal|virtual]
data at volumes controlled by a particular CU. When
statistics are exported to a ZIP file, multiple ZIP files whose
names are beginning with LDEV_ will be output. For details
on the statistics exported by this operand, see
When you specify variables LDKC-CU-id, you can narrow
the range of LDKC:CUs that control the volumes whose
monitoring data are to be exported. LDKC-CU-id is an ID
of a LDKC:CU. The colon (:) indicates a range. For
example, 000:105 indicates LDKC:CUs from 00:00 to
01:05.
Ensure that the LDKC-CU-id value on the left of the colon
is smaller than the LDKC-CU-id value on the right of the
colon. For example, you can specify LDEVEachOfCU
000:105
, but you cannot specify LDEVEachOfCU
105:000
.
If internal is specified, you can export statistics about
volumes in the parity group. If virtual is specified, you can
export statistics about volumes in the external volume group,
V-VOL group, or migration volume group.
If LDKC-CU-id, internal or virtual is not specified, the
monitoring data of all the volumes will be exported. Either
one of LDKC-CU-id, internal, or virtual can be specified.
Use this operand when you want to export statistics about
performance information on each processor blades. When
PhyMPPK
statistics are exported to a ZIP file, the filename is
PHY_MPPK.ZIP. For details on the statistics exported by
this operand, see
.
Examples
The following example exports statistics about host bus adapters:
group PortWWN
The following example exports statistics about three ports (CL1-A, CL1-B, and CL1-C):
group Port CL1-A:CL1-C
The following example exports statistics about six ports (CL1-A to CL1-C, and CL2-A to CL2-C)
group Port CL1-A:CL1-C CL2-A:CL2-C
The following example exports statistics about the parity group 1-3:
group PG 1-3:1-3
The following example exports statistics about the parity group 1-3 and other parity groups whose
ID is larger than 1-3 (for example, 1-4 and 1-5):
group PG 1-3:
The following example exports statistics about the external volume groups E1-1 to E1-5:
group PG E1-1:E1-5
The following example exports statistics about the parity group 1-3 and other parity groups whose
ID is smaller than 1-3 (for example, 1-1 and 1-2):
group LDEV:1-3
The following example exports statistics about LU paths for the host group (host storage domain)
ID 01 for the port CL1-A:
group LU CL1-A.01:CL1-A.01
Export Tool command reference