Summary, Monitored cus tab, Monitored wwns tab – HP XP P9500 Storage User Manual
Page 107
![background image](/manuals/397410/107/background.png)
Summary
The summary information of monitoring is displayed.
Description
Item
Monitoring statuses of following:
Monitoring Switch
•
Enabled: Performance Monitor is monitoring the storage system.
•
Disabled: The storage system is not being monitored.
Current sampling interval, from 1 to 15 minutes, for which statistics are collected
during short-range monitoring.
Sample Interval
This value is available when Enabled is selected in the Monitoring Switch field.
If Disabled is selected, a hyphen appears.
Number, from 0 to 255, of CUs currently being monitored.
Number of Monitored CUs
Number, from 0 to 65280, of LDEVs currently being monitored.
Number of Monitored LDEVs
Number, from 0 to 2048, of WWNs currently being monitored.
Number of Monitored WWNs
Click to open the Monitor Performance window where you can specify the
monitoring objects and monitoring period. Up to 8 objects can be specified in
one graph panel. Up to 16 objects can be specified in 4 graph panels.
Monitor Performance
Click to open the Edit Monitoring Switch window where you can start and stop
performance monitoring, and specify how often to monitor statistics.
Edit Monitoring Switch
Monitored CUs tab
Use this tab to view information about the CUs that are currently being monitored.
Description
Item
Number of monitored CUs.
CU
Number of LDEVs included in the monitored CUs.
Number of LDEVs
Click to open the Edit CU Monitor Mode window, where you can change
the monitoring status.
Edit CU Monitor Mode
Click to open the View CU Matrix window, where you can view the
monitoring status of all the CUs in one LDKC.
View CU Matrix
Click to export the monitoring data to the CSV file.
Export
Monitored WWNs tab
Use this tab to view information about the WWNs that are currently being monitored.
Description
Item
Name of the port of the monitored WWN.
Port ID
Host bus adapter ID of the monitored WWN.
HBA WWN
A WWN name is up to 64 alphanumeric characters and some signs.
WWN Name
Following statuses of the port connected with WWN.
Status
•
Normal: All WWNs connected with the port are monitoring target
objects.
•
Non-Integrity: A part of WWNs are not monitoring target objects
among WWNs connected with the port.
Click to open the Edit WWN Monitor Mode window.
Edit WWN Monitor Mode