Power-on self-test, Power-on self-test -9 – HP ProLiant DL760 G2 Server User Manual
Page 189

Server Power
7. Watch for memory system initialization. As the system initializes, the memory
cartridge power LEDs on all five memory cartridges begin blinking. After the
memory system is initialized, all memory cartridges power LEDs will illuminate
solid.
8. The server begins the Power-On Self-Test (POST) sequence. The IMD displays
each step of the POST sequence.
Power-On Self-Test
As the POST process continues during server power-up, you need to:
1. Check for the IMD messages about:
a. Server name
b. LCD firmware
c. System initialization
d. PCI auto configuration
e. Video
f. Processors
2. Check the IMD video initialization message. If a monitor is connected, refer to
the HP initialization screen.
3. Check the IMD memory test message. The monitor displays the memory
initialization, memory detected, and redundant memory.
4. Check the IMD processors message. The monitor displays the number, speed,
and cache size of the processors.
5. Check for IMD messages about:
a. Diskette drive
b. Option ROM
c. SCSI devices
HP ProLiant DL760 Generation 2 Server User Guide
7-9
HP CONFIDENTIAL
Writer: Jennifer Hayward File Name: h-ch7 Server Power.doc
Codename: Pioneer Part Number: 201264-002 Last Saved On: 6/17/03 10:08 AM