HP Insight Management-Software User Manual
Page 90
•
Confirms that the target VC Domain Group that the server profile will be exported to has
a status of Configuration in synch. VC Domain Groups with other statuses such as the
following list cannot receive exported server profiles:
◦
Under maintenance
◦
Incompatible firmware
•
Ensures that the target VC Domain Group virtual MAC, WWN and Serial Number range
types are compatible with addresses allocated in the selected server profile. See
) for more information.
If any of the
conditions are not met, the prevalidation window (
) displays an error for this step.
3.
Feature compatibility validations—The target VC Domain Group must support all the connections
and features defined by the selected server profile. VCEM performs the following validations
in this step:
•
Ensures that the target VC Domain Group firmware mode supports iSCSI if the server
profile contains iSCSI connections
•
Ensures that the target VC Domain Group supports FC connections if the server profile
contains them.
•
Confirms that the target VC Domain Group firmware mode supports FCoE if the server
profile contains FCoE connections.
If any
condition is not attained, the prevalidation window (
) displays an error status for this step.
4.
Feature Validations related to Network—VCEM performs the following validations related to
the Ethernet connections data exportation:
•
Confirms that the target VC Domain Group supports server profiles with Ethernet
connections defined as Multiple Networks. If the server profile has an Ethernet connection
using Multiple Networks, then the target VC Domain Group firmware mode must support
the server VLAN mapping feature, otherwise
displays an error status in the
prevalidation window (
Move profile prevalidation table (page 88)
).
•
Ensures that the Ethernet networks used in the selected server profile exist in the target
VC Domain Group. If any network used in the profile does not exist in the target VC
Domain Group, VCEM automatically removes the reference to that network from the server
profile in order to allow it to be exported to the target VC Domain Group. Network names
used by the server profile Ethernet or iSCSI connections should match the network names
defined in the target VC Domain Group. Otherwise, the network name will be
disassociated from the specific server profile connection (Ethernet or iSCSI) and
displays a configuration status in the prevalidation window (
). In this case after the export server profile operation is completed , you
must edit the server profile in the target VC Domain Group and assign an existing network
to the Ethernet or iSCSI connection so that the server profile network connectivity works
properly.
•
Confirms that the network port speed defined in the server profile is less than or equal to
the maximum port speed defined for the target VC Domain Group network, otherwise
displays an error status in the prevalidation window.
•
Ensures that all VLAN network names for the Ethernet connections defined as multiple
connections exist in the target VC Domain Group. VLAN network names used by a server
profile connection that is defined as Multiple Networks must match the network names
90
Managing server profiles