beautypg.com

HP Insight Management-Software User Manual

Page 33

background image

Figure 15 Server profile configured with multiple FCoE connections

To disable this feature:
1.

Log on to HP Virtual Connect Manager.

2.

Expand Server Profiles in the navigation pane and select the server profile with Multiple FCoE
connections per I/O bay that you want to delete.

3.

Right-click and select Delete Connection until only one connection per I/O bay remains.

NOTE:

Deleting connections until only one connection per I/O bay remains applies to FC

connections as well as FCoE connections.

FCoE fabrics are not supported.
To disable this feature, delete all the SAN Fabrics that are using uplink ports from the FCoE capable
Virtual Connect modules as outlined in the following procedure:
1.

Log on to HP Virtual Connect Manager.

2.

Expand SAN Fabrics in the navigation pane. The SAN Fabrics window is displayed.

3.

Select External Connections and choose the connection you want to delete.

4.

Right-click and select Delete as displayed in

Figure 16

:

Requirements for adding a VC Domain to a VC Domain Group

33

This manual is related to the following products: