Monitor script remove, Monitor start, Monitor script remove monitor start – HP Storage Mirroring Software User Manual
Page 280
![background image](/manuals/397017/280/background.png)
A
-
17
Monitor Script Remove
Monitor Start
Command
MONITOR SCRIPT REMOVE
Description
Specifies the scripts that should not be run during the failover and failback processes
Syntax
MONITOR SCRIPT REMOVE <
type
> [
monitor
]
Options
!
type
—Any of the following script types:
!
PREFAILOVER
—Specifies that the file is a pre-failover script to be run on the target before
failover occurs
!
POSTFAILOVER
—Specifies that the file is a post-failover script to be run on the target after
failover occurs
!
PREFAILBACK
—Specifies that the file is a pre-failback script to be run on the target before
failback occurs
!
POSTFAILBACK
—Specifies that the file is a post-failback script to be run on the target after
failback occurs
!
SRCPOSTFAILBACK
—Specifies that the file is a pre-failback script to be run on the source
after failback occurs
!
monitor
—Name of the source machine designated as the monitor
Examples
!
monitor script remove prefailback
!
monitor script remove postfailover
Notes
If you do not specify a monitor, the current source designated as the monitor will be used. If you
have not identified a monitor, you will receive an error message stating that a monitor has not been
selected.
Command
MONITOR START
Description
The configured failover target starts monitoring the source machine that was designated as the
monitor.
Syntax
MONITOR START <
monitor
> [ON <
target_machine
>]
Options
!
monitor
—Name of the source machine designated as the monitor
!
target_machine
—Name of the target machine that will be monitoring the source machine
Examples
monitor start indy on jersey