HP Storage Mirroring Software User Manual
Page 195
13
-
15
DblTake
16391
Error
An error occurred while accessing the
replication pagefile. Replication has been
stopped. The paging of replication ops is
disabled. The last Word in the Data
Window is the NT status code.
This error may be caused because the
drive is out of space, is not an NTFS
partition, is possibly going bad, and so on.
Contact technical support.
16392
Info
An internal error occurred. The last Word
in the Data Window indicates the internal
error code.
Contact technical support if this event
occurs again.
16393
Info
Failed to build data structure for "%2"
because of insufficient OS stack space.
This file will not be replicated.
If the specified file is in the replication set,
reboot the server and contact technical
support if this event occurs again. If the file
is not contained in the replication set, this
message can be disregarded.
16394
Error
Dblhook detected a memory error,
possibly caused by faulty hardware or a
bad driver. The last Word in the Data
Window indicates the internal error code.
This message may be caused by another
application attempting to access memory
reserved by Storage Mirroring. Contact
technical support if this event occurs again.
16395
Warning
Dblhook detected a hard link for a file.
The volume GUID and file ID are stored in
the Data Window. This file will not be
replicated.
Files with hard links are not replicated.
16396
Info
The driver made more than one pass
before finding a valid buffer. The last Word
in the Data Window indicates the number
the tries.
Contact technical support if this event
occurs again.
DTCounters
1000
Error
An exception occurred: %1
Run the Storage Mirroring installation and
select Repair. Contact technical support if
this event occurs again.
1001
Error
The Double-Take counter DLL could not
initialize the statistics handler object to
gather performance data.
Run the Storage Mirroring installation and
select Repair. Contact technical support if
this event occurs again.
1002
Error
The Double-Take counter DLL could not
map shared memory file containing the
performance data.
Run the Storage Mirroring installation and
select Repair. Contact technical support if
this event occurs again.
1003
Error
The Double-Take counter DLL could not
open the "Performance" key in the
Double-Take section of the registry.
Run the Storage Mirroring installation and
select Repair. Contact technical support if
this event occurs again.
1004
Error
The Double-Take counter DLL could not
read the "First Counter" value under the
Double-Take\Performance Key.
Run the Storage Mirroring installation and
select Repair. Contact technical support if
this event occurs again.
1005
Error
The Double-Take counter DLL read the
"First Help" value under the
Double-Take\Performance Key.
Run the Storage Mirroring installation and
select Repair. Contact technical support if
this event occurs again.
1006
Error
The Double-Take counter DLL could not
create event handler for the worker
thread.
Run the Storage Mirroring installation and
select Repair. Contact technical support if
this event occurs again.
Failback
5200
Info
Failback completed for %1.
No action required.
5201
Info
IP address %1 was removed from target
machine's %2 adapter.
No action required.
5202
Error
Unable to Failback properly because IP
address %1 was missing a corresponding
SubNet Mask.
Contact technical support.
Category
ID
Severity
Message
Required Response