HP Integrity NonStop H-Series User Manual
Page 79

SETUPRUN and NSKUNPK Error Messages
IPSetup User’s Guide—524733-007
B-23
NSKUNPK Errors by File Name
SIPUTILC Error Class: NSK LIBRARY FUNCTION FAILURE
6004/6005
Cause. SETUPRUN is unable to determine the size of a NonStop file.
Recovery. This error might be transient. Restart the program. If this problem persists,
contact your support representative.
6006
Cause. FILENAME_FINDSTART_ failed when looking for an empty subvolume for
version 3 A0CINFO file reconstitution.
Recovery. This error might be transient. Restart the program. If this problem persists,
contact your support representative.
6007
Cause. FILE_OPEN_ failed attempting to open the reconstituted version 3 A0CINFO
file in the scratch subvolume.
Recovery. Assume this error is transient. Eliminate any residual files from scratch
subvolumes and existing files in the DSV. Then restart the program. If this problem
persists, contact your support representative.
FILE_GETINFOLISTBYNAME_ failure - unable to continue.
FILENAME_FINDSTART_ failure.
DSV dsv-name cannot be unpackaged.
’FILE_OPEN_’ NSK library procedure failed opening a file:
file-name
Unable to place version 2 A0CINFO file into DSV.
DSV cannot be reconstituted: dsv-name