SETUPRUN and NSKUNPK Error Messages

IPSetup User’s Guide524733-007

B-9

NSKUNPK Errors by File Name

Recovery. Contact your support representative.

SIPDRVRC Error Class: CALLER-SPECIFIED DATA

1000

Cause. NSKUNPK was invoked without the name of a base package file name (for
example, R7887000), which is a required parameter.

Recovery. Specify a base package file name when running NSKUNPK (for example,
RUN NSKUNPK R7887000).

1001

Cause. NSKUNPK was invoked with a base package file name longer than eight
characters, which is invalid for a NonStop file name.

Recovery. Specify a valid base package file name when running NSKUNPK (for
example, RUN NSKUNPK R7887000).

SIPDRVRC Error Class: DSM/SCM LIBRARY FUNCTION
FAILURE

2000

Cause. NSKPACK is incompatible with NSKUNPK.

Recovery. Overlay the existing NSKUNPK with the version on the software delivery
medium (CD-ROM or DVD), or order a new delivery medium or different T0082 product
version.

A ’base’ package file name must be specified.

’Base’ package name too long; NSK file name length limit is
8.

This NSKUNPK version (T0082v xx) is incompatible with its
NSKPACK counterpart.
Acquire a newer version of NSKUNPK.