ADDR = 0x1E4-E7: Receive FIFO Overflow Error
ADDR
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Bit name
0x1E4
RX_FIFO_OF_ERR [7:0]
0x1E5
RX_FIFO_OF_ERR [15:8]
0x1E6
Fixed 0
0x1E7
Fixed 0
R/W
RO
Value
0
after
reset
RX_FIFO_OF_ERR
is the RX FIFO Overflow Error counter. It is non-resetable except that a hard or soft
reset will clear it. After reaching its max value the counter starts over from zero again. This counter is
incremented each time there is a FIFO overflow and hence a frame is discarded.
ADDR = 0x1E8-EB: Receive FIFO Underrun Error
ADDR
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Bit name
0x1E8
RX_FIFO_UR_ERR [7:0]
0x1E9
RX_FIFO_UR_ERR [15:8]
0x1EA
Fixed 0
0x1EB
Fixed 0
R/W
RO
Value
0
after
reset
RX_FIFO_UR_ERR
is the RX FIFO Underrun Error counter. It is non-resetable except that a hard or soft
reset will clear it. After reaching its max value the counter starts over from zero again. This counter is
incremented each time there is a FIFO underrun and hence a frame is discarded.