ADDR = 0x194-0x197: TX_ER Error Counter

ADDR

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Bit name

0x194

TX_ER_ERR [7:0]

0x195

TX_ER_ERR [15:8]

0x196

TX_ER_ERR [23:16]

0x197

Fixed 0

R/W

RO

Value

0

after
reset

TX_ER_ERR

is the TX_ER Error counter. It is non-resetable except that a hard or soft reset will clear it.

After reaching its max value the counter starts over from zero again.

This counter is incremented by frames where TX_ER was detected active while the frame was being
received but did not cause a FIFO error.

ADDR = 0x198-0x19B: TX FIFO Overflow Error

ADDR

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Bit name

0x198

TX_FIFO_OF_ERR [7:0]

0x199

TX_FIFO_OF_ERR [15:8]

0x19A

Fixed 0

0x19B

Fixed 0

R/W

RO

Value

0

after
reset

TX_FIFO_OF_ERR

is the TX_FIFO Overflow Error counter. It is non-resetable except that a hard or soft

reset will clear it. After reaching its max value the counter starts over from zero again.

This counter is incremented each time there is a FIFO overflow and hence a frame is discarded.