11

Signal name

Pin #

Type(I/O)

Signal description

TX_E1_DATA

126

I

TRANSMIT E1 DATA: Local orderwire channel data byte
(E1) to be inserted by the HDMP-3001 into the outgoing
SONET data stream.

TX_E2_DATA

127

I

TRANSMIT E2 DATA: Express orderwire channel data byte
(E2) to be inserted by the HDMP-3001 into the outgoing
SONET data stream.

TX_F1_DATA

128

I

TRANSMIT F1 DATA: Maintenance channel data byte (F1)
to be inserted by the HDMP-3001 into the outgoing SONET
data stream.

TX_E1E2F1_CLK

129

O

TRANSMIT E1/E2/F1 DATA REFERENCE CLOCK: A 64 kHz clock
reference output for E1/E2/F1 data to be inserted by the
HDMP-3001 into the outgoing SONET data stream.

TX_LDCC_DATA

123

I

TRANSMIT LINE DCC DATA: Input for the Line Data
Communications Channel (DCC) to be inserted by the HDMP-3001
into the outgoing SONET data stream.

TX_LDCC_CLK

124

O

TRANSMIT LINE DCC REFERENCE CLOCK: A 576 kHz clock
reference for Line DCC data to be inserted by the
HDMP-3001 into the outgoing SONET data stream. The
TX_LDCC_DATA inputs are sampled on the falling edge of
TX_LDCC_CLK.

TX_SDCC_DATA

117

I

TRANSMIT SECTION DCC DATA: Input for the Section
Data Communications Channel (DCC) to be inserted into the
outgoing SONET data stream from the HDMP-3001.

TX_SDCC_CLK

118

O

TRANSMIT SECTION DCC REFERENCE CLOCK:
A 192 kHz clock reference for Section DCC data to be inserted
by the HDMP-3001 into the outgoing SONET data stream. The
TX_SDCC_DATA inputs are sampled on the falling edge of
TX_LDCC_CLK.

TX_8K_CLK

132

O

8kHz TRANSMIT CLOCK: A general purpose 8kHz
buffered clock derived from TX_SONETCLK which may be
used for external clock reference purposes.