beautypg.com

Agilent Technologies HDMP-3001 User Manual

Page 111

background image

111

8.2 Microprocessor Bus Timing - Read Cycle.

Figure 30. Microprocessor Read Cycle Timing.

* RDYB is re-clocked twice by the microprocessor clock in addition to the timing shown. This
adds an additional delay of between one and two microprocessor clock cycles.

VALID

t

7

t

10

t

9

INVALID

VALID

CAPTURED

Hi - Z

Hi - Z

Hi - Z

Hi - Z

A[8:0]

CSB

WRB

RDB

D[7:0] (IN)

D[7:0] (OUT)

RDYB

*

GPIO[15:0]

t

11

t

12

t

1

t

8

t

5

BIDIR

OUTPUTS

INPUTS