Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Bit name Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
J1_OOF
R/W
—
—
—
—
—
—
—
R
Value
0
0
0
0
0
0
0
1
after
reset
ADDR=0x133: Receive J1 OOF
Bits 7-1: Reserved
Bit 0:
J1_OOF:
The J1 monitor framer searches for 15 consecutive J1 bytes that have a zero in their
MSB, followed by a J1 byte with a one in its MSB. When J1_OOF = 0, it indicates this pattern is
found, the framer goes into frame. When J1_OOF = 1, it indicates this pattern match is lost (three
consecutive J1 bytes with MSB errors).
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Bit name RX_J1[0]_[7:0]
•
•
•
RX_J1[63]_[7:0]
R/W
R
Value
0
0
0
0
0
0
0
0
after
reset
ADDR=0x134 –0x173: Receive J1 Bytes
Bits 7-0: RX_J1[0:63]_[7:0]
In SONET mode, the RX_J1[63:0]_[7:0] registers hold the last captured path trace frame.