beautypg.com

Agilent Technologies HDMP-3001 User Manual

Page 113

background image

113

RX_SONETCLK

RX_DATA[7:0]

RX_FRAME_IN

t

HRDFC

t

HFIFC

t

SRDTC

t

SFITC

Label

Parameter

Min

Max

Units

RX_SONETCLK

RX_SONETCLK frequency

19.44-20ppm

19.44+20ppm

MHz

t

SRDTC

Setup RX_DATA to RX_CLK high

5

ns

t

HRDFC

Hold RX_DATA from RX_CLK high

5

ns

t

SFITC

Setup RX_FRAME_IN to RX_CLK high

5

ns

t

HFIFC

Hold RX_FRAME_IN from RX_CLK high

5

ns

8.5 TOH Interface E1/E2/F1 Transmit Timing.

TX_E1E2F1_CLK

TX_E1_DATA
TX_E2_DATA

TX_F1_DATA

t

HE1FC

t

SE1TC

t

HE2FC

t

SE2TC

t

HF1FC

t

SF1TC

Label

Parameter

Min

Typ.

Max

Units

TX_E1E2F1_CLK

TX_E1E2F1_CLK frequency

64

kHz

t

SE1TC

Setup TX_E1_DATA to TX_E1E2F1_CLK high

100

ns

t

HE1FC

Hold TX_E1_DATA from TX_E1E2F1_CLK high

100

ns

t

SE2TC

Setup TX_E2_DATA to TX_E1E2F1_CLK

100

ns

t

HE2FC

Hold TX_E2_DATA from TX_E1E2F1_CLK high

100

ns

t

SF1TC

Setup TX_F1_DATA to TX_E1E2F1_CLK high

100

ns

t

HF1FC

Hold TX_F1_DATA from TX_E1E2F1_CLK high

100

ns

Figure 32. Line Interface Receive Timing.