63

ADDR=0x0FF: Receive TOH Monitor Control

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Bit name

K2_CONSEC_NUM[3:0]

RX_LOS_

RX_LOS_

RX_FRAM_

RX_LOF_

LEVEL

INH

INH

ALG

R/W

R/W

R/W

R/W

R/W

R/W

Value

0

1

0

1

0

0

0

0

after
reset

Bits 7-4: K2_CONSEC_NUM[3:0]: This 4 bit register is used to keep track of the number of consecutive

occurrences of LAIS and LRDI in order for the presence/absence of LAIS or LRDI to be detected
and the monitors to be updated accordingly.

Bit 3:

RX_LOS_LEVEL

is set to indicate RX_LOS is active low.

Bit 2:

RX_LOS_INH

is set to inhibit the contribution of RX_LOS to LRDI.

Bit 1:

RX_FRAM_INH:

If 1, the HDMP-3001 receive framer is enable and the parallel input signal is not

assumed to be byte aligned. If 0, the receive framer in the HDMP-3001 is bypassed, and it requires
a frame start condition, RX_FRAME_IN, as well as data and clock.

Bit 0:

RX_LOF_ALG:

If 1, RX_LOF will be cleared after RX_OOF is inactive for 8 consecutive frames.

If 0, RX_LOF will be cleared after RX_OOF is inactive for 24 consecutive frames.

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Bit name Reserved

Reserved

Reserved

Reserved

RX_FRAME_POSITION[3:0]

R/W

R/W

Value

0

0

0

0

0

0

0

0

after
reset

ADDR=0x101: Receive Framer Position Control

Bits 7-4: Reserved

Bits 3-0: RX_FRAME_POSITION [3:0] – These four bits control the relationship between the data

bytes on the input bus RX_DATA [7:0] and the RX_FRAME_IN clock pulse. Please refer to
Table 21.