Agilent Technologies HDMP-3001 User Manual
Page 63
![background image](/manuals/39388/63/background.png)
63
ADDR=0x0FF: Receive TOH Monitor Control
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Bit name
K2_CONSEC_NUM[3:0]
RX_LOS_
RX_LOS_
RX_FRAM_
RX_LOF_
LEVEL
INH
INH
ALG
R/W
R/W
R/W
R/W
R/W
R/W
Value
0
1
0
1
0
0
0
0
after
reset
Bits 7-4: K2_CONSEC_NUM[3:0]: This 4 bit register is used to keep track of the number of consecutive
occurrences of LAIS and LRDI in order for the presence/absence of LAIS or LRDI to be detected
and the monitors to be updated accordingly.
Bit 3:
RX_LOS_LEVEL
is set to indicate RX_LOS is active low.
Bit 2:
RX_LOS_INH
is set to inhibit the contribution of RX_LOS to LRDI.
Bit 1:
RX_FRAM_INH:
If 1, the HDMP-3001 receive framer is enable and the parallel input signal is not
assumed to be byte aligned. If 0, the receive framer in the HDMP-3001 is bypassed, and it requires
a frame start condition, RX_FRAME_IN, as well as data and clock.
Bit 0:
RX_LOF_ALG:
If 1, RX_LOF will be cleared after RX_OOF is inactive for 8 consecutive frames.
If 0, RX_LOF will be cleared after RX_OOF is inactive for 24 consecutive frames.
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Bit name Reserved
Reserved
Reserved
Reserved
RX_FRAME_POSITION[3:0]
R/W
—
—
—
—
R/W
Value
0
0
0
0
0
0
0
0
after
reset
ADDR=0x101: Receive Framer Position Control
Bits 7-4: Reserved
Bits 3-0: RX_FRAME_POSITION [3:0] – These four bits control the relationship between the data
bytes on the input bus RX_DATA [7:0] and the RX_FRAME_IN clock pulse. Please refer to
Table 21.