Agilent Technologies HDMP-3001 User Manual
Page 94
![background image](/manuals/39388/94/background.png)
94
ADDR = 0x1CD: LAPS Mode
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Bit name Reserved
Reserved
RX_ADR_
RX_CNT_
RX_SAPI_
RX_ADR_
RX_CNT_
RX_SAPI_
REM_INH
REM_INH
REM_INH
CHECK_
CHECK_
CHECK_
INH
INH
INH
R/W
—
—
R/W
R/W
R/W
R/W
R/W
R/W
Value
0
0
0
0
0
0
0
0
after
reset
Bits 7-6: Reserved
Bit 5:
RX_ADR_REM_INH
is set to inhibit the removal of the received Address field. When set, the
Address field is prepended to the MAC Payload. When cleared, the Address field is not forwarded
through the MII interface.
Bit 4:
RX_CNT_REM_INH
is set to inhibit the removal of the received Control field. When set, the
Control field is prepended to the MAC Payload. When cleared, the Control field is not forwarded
through the MII interface.
Bit 3:
RX_SAPI_REM_INH
is set to inhibit the removal of the received SAPI field. When set, the SAPI
field is prepended to the MAC Payload. When cleared, the SAPI field is not forwarded through the
MII interface.
Bit 2:
RX_ADR_CHECK_INH
is set to inhibit the checking of the received Address field.
Bit 1:
RX_CNT_CHECK_INH
is set to inhibit the checking of the received Control field.
Bit 0:
RX_SAPI_CHECK_INH
is set to inhibit the checking of the received SAPI field.