beautypg.com

Agilent Technologies HDMP-3001 User Manual

Page 57

background image

57

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Bit name TX_J0[0]_[7:0]

TX_J0[15]_[7:0]

R/W

R/W

Value

0

0

0

0

0

0

0

0

after
reset

ADDR=0x09F –0x0AE: Transmit J0 Bytes 1 – 16

Bits 7-0: TX_J0[0:15]_[7:0]: Transmit J0 (Section Trace) – When enable, the HDMP-3001 will

continuously transmit in the 16-byte pattern in these registers in the J0 byte. The bytes are
transmitted in descending order starting from TX_J0[15]_[7:0].

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Bit name

TEST_K2[7:0]

R/W

R/W

Value

0

0

0

0

0

0

0

0

after
reset

ADDR=0x0B0: Transmit K2 Byte

TX_K2[7:3]:

These bits are automatic protection switching (APS) signaling.

TX_K2[2:0]:

These bits are controlled by 3 sources. In order of priority, these are:

If TX_LAIS is set, they are transmitted as 111.

If LRDI_INH is cleared, and if any of (RX_LOS and not RX_LOS_INH), RX_LOF, or RX_LAIS

is set, they are transmitted as 110 for a min. of 20 frames.

Else, they are transmitted as TX_K2[2:0]

In SDH, the three LSBs of the K2 byte are used as an AIS or Remote Defect Indication(RDI)
at the line/MS level.

In SONET, the three LSBs of K2 are used as APS signaling.