Agilent Technologies HDMP-3001 User Manual
Page 70
70
ADDR=0x122: Receive Pointer Interpreter Mask
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Bit name Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
RX_LOP_D
RX_PAIS_
_MASK
D_MASK
R/W
—
—
—
—
—
—
R/W
R/W
Value
0
0
0
0
0
0
1
1
after
reset
Bits 7-2: Reserved
Bit 1:
RX_LOP_D_MASK:
RX_LOP delta bit mask
Bit 0:
RX_PAIS_D_MASK:
RX_PAIS delta bit mask
These bits are used to enable/disable status reporting of the corresponding event bits. If set, the reporting
status of the corresponding bit in the event register is disabled.
ADDR=0x126: Receive Pointer Interpreter Delta
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Bit name Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
RX_LOP_D
RX_PAIS_
D
R/W
—
—
—
—
—
—
W1C
W1C
Value
0
0
0
0
0
0
0
0
after
reset
Bits 7-2: Reserved
Bit 1:
RX_LOP_D:
RX_LOP delta bit
Bit 0:
RX_PAIS_D:
RX_PAIS delta bit
These bits are set if a change in state of the corresponding event bit occurs. They are cleared by writing a
one to them.