beautypg.com

Agilent Technologies HDMP-3001 User Manual

Page 70

background image

70

ADDR=0x122: Receive Pointer Interpreter Mask

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Bit name Reserved

Reserved

Reserved

Reserved

Reserved

Reserved

RX_LOP_D

RX_PAIS_

_MASK

D_MASK

R/W

R/W

R/W

Value

0

0

0

0

0

0

1

1

after
reset

Bits 7-2: Reserved

Bit 1:

RX_LOP_D_MASK:

RX_LOP delta bit mask

Bit 0:

RX_PAIS_D_MASK:

RX_PAIS delta bit mask

These bits are used to enable/disable status reporting of the corresponding event bits. If set, the reporting
status of the corresponding bit in the event register is disabled.

ADDR=0x126: Receive Pointer Interpreter Delta

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Bit name Reserved

Reserved

Reserved

Reserved

Reserved

Reserved

RX_LOP_D

RX_PAIS_
D

R/W

W1C

W1C

Value

0

0

0

0

0

0

0

0

after
reset

Bits 7-2: Reserved

Bit 1:

RX_LOP_D:

RX_LOP delta bit

Bit 0:

RX_PAIS_D:

RX_PAIS delta bit

These bits are set if a change in state of the corresponding event bit occurs. They are cleared by writing a