ADDR = 0x1F4-7: Receive Minimum Frame Size Violations [23:0]
ADDR
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Bit name
0x1F4
RX_MIN_ERR [7:0]
0x1F5
RX_MIN_ERR [15:8]
0x1F6
RX_MIN_ERR [23:16]
0x1F7
Fixed 0
R/W
RO
Value
0
after
reset
RX_MIN_ERR
is the RX minimum frame size violation counter. It is non-resetable except that a hard or soft
reset will clear it. After reaching its max value the counter starts over from zero again. This counter is
incremented by each frame that did not increment any of the RX_FIFO_UR_ERR or RX_FIFO_OF_ERR
counters, but contained fewer than RX_MIN_SIZE bytes and checking was turned on.
ADDR = 0x1F8-B: Receive Maximum Frame Size Violations [15:0]
ADDR
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Bit name
0x1F8
RX_MAX_ERR [7:0]
0x1F9
RX_MAX_ERR [15:8]
0x1FA
Fixed 0
0x1FB
Fixed 0
R/W
RO
Value
0
after
reset
RX_MAX_ERR
is the RX maximum frame size violation counter. It is non-resetable except that a hard or
soft reset will clear it. After reaching its max value the counter starts over from zero again. This counter is
incremented by each frame that did not increment any of the RX_FIFO_UR_ERR or RX_FIFO_OF_ERR
counters, but contained more than RX_MAX_SIZE bytes and checking was turned on.