Agilent Technologies HDMP-3001 User Manual
Page 9
9
Signal name
Pin #
Type(I/O)
Signal description
TX_FRAME_SFP
125
O
TRANSMIT FRAME POSITION OUTPUT INDICATOR: Frame position
indication signal is active high and indicates the SONET frame
position on the TX_DATA [7:0] bus. Updated on the rising edge of
TX_SONETCLK. This signal is also used for the outer board to start
sending the first bit (MSB) of the serial data E1, E2, F1, SDCC,
and LDCC.
TX_SONETCLK
133
I
TRANSMIT SONET CLOCK: TX_SONETCLK is the transmit output
clock to the line side, and provides timing for the transmit data
bus and frame position indication outputs. This clock should be
19.44 MHz
±
20 ppm.
LOC_TX
115
O
Loss of SONET_TX clock.
LOC_RX
116
O
Loss of SONET_RX clock.
Signal name
Pin #
Type(I/O)
Signal description
SYS_25M_CLK
88
I
Drives the two MII clocks in PHY mode, TX_CLK and
RX_CLK. It is also used to monitor the TX_SONETCLK
and RX_SONETCLK.
The requirement for this clock is 25 MHz
±
100 ppm.
P_TX_CLK_M_RX_CLK
104
I/O (Int. PU)
PHY mode: transmit clock output. Derived from
SYS_25M_CLK.
MAC mode: receive clock input. Nominally 25 MHz.
P_TXD_M_RXD[0]
108
I
PHY mode: transmit data nibble.
P_TXD_M_RXD[1]
107
MAC mode: receive data nibble.
P_TXD_M_RXD[2]
106
P_TXD_M_RXD[3]
105
P_TX_EN_M_RX_DV
109
I
PHY mode: transmit data enable.
MAC mode: receive data valid.
P_RX_CLK_M_TX_CLK
93
I/O (Int. PU)
PHY mode: receive clock output. Derived from
SYS_25M_CLK.
MAC mode: transmit clock input. Nominally 25 MHz.
P_RXD_M_TXD[0]
97
O (T/S)
PHY mode: receive data nibble.
P_RXD_M_TXD[1]
96
MAC mode: transmit data nibble.
P_RXD_M_TXD[2]
95
P_RXD_M_TXD[3]
94
P_RX_DV_M_TX_EN
98
O (T/S)
PHY mode: receive data valid.
MAC mode: transmit data enable.
P_RX_ER_M_TX_ER
103
O (T/S)
PHY mode: receive error.
MAC mode: transmit error.
P_TX_ER_M_RX_ER
112
I
PHY mode: transmit error.
MAC mode: receive error.
Table 2. MII Interface Pins Description
(continues)