beautypg.com

Agilent Technologies HDMP-3001 User Manual

Page 76

background image

76

ADDR=0x174: Receive Path Delta

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Bit name Reserved

Reserved

Reserved

RX_C2_D

RX_G1_D

RX_UNEQ_

RX_PLM_D

Reserved

D

R/W

W1C

W1C

W1C

W1C

Value

0

0

0

0

0

0

0

after
reset

Bits 7-5: Reserved

Bit 4:

RX_C2_D:

RX_C2 delta bit. It is set when a new value is stored in RX_G1 [2:0].

Bit 3:

RX_G1_D:

RX_G1 delta bit. It is set when RX_UNEQ changes state.

Bit 2:

RX_UNEQ_D:

RX_UNEQ delta bit. It is set when RX_PLM changes state.

Bit 1:

RX_PLM_D:

RX_PLM delta bit. It is set when a new value is stored in RX_C2 [7:0]

Bit 0:

Reserved

Write one to these bits to clear them.

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Bit name EXP_C2 [7:0]

R/W

R/W

Value

0

0

0

1

1

0

0

0

after
reset

ADDR=0x176: Expected C2 Byte

Bits 7-0: EXP_C2 [7:0]

The received C2 bytes are monitored so that reception of the correct type of payload can be verified. When
a consistent C2 value is received for five consecutive frames, it is written to RX_C2 [7:0], and the RX_C2_D
delta bit is set. The expected value of the received C2 bytes is provided in EXP_C2 [7:0]. Its value after
reset is 0x18 which indicates the mapping of a LAPS framed signal. If the received value does not match the
expected value, and it is NOT:

• all zeros unequipped label

• 0x01 equipped, non-specific label

• 0xFC payload defect label

• 0xFF reserved label

then the Payload Label Mismatch register bit, RX_PLM, is set to one.
If the current accepted value is the all zeros unequipped label, and EXP_C2[7:0]

0, then the

unequipped register bit, RX_UNEQ, is set to one.